Wima MKS2 0.1uf/63 v/10%

Price :

2.500 rupiah/pcs

2.250 rupiah/10pcs

 


Electrical Data
Capacitance range:
0.01 µF to 10 µF (E12-values on request)
Rated voltages:
50VDC, 63VDC, 100VDC, 250VDC, 400VDC, 630VDC
Capacitance tolerances:

±20%, ±10%, ±5%
Operating temperature range:
-55°C to +100°C
Test specifications:
In accordance with IEC 60384-2 and EN 130400
Climatic test category:
55/100/21 in accordance with IEC
Insulation resistance
at +20°C:
Test voltage: 1.6 Ur, 2 sec
Voltage derating:
A voltage derating factor of 1.25% per K must be applied from +85°C for DC voltages and from +75°C for AC voltages.
Reliability:
Operational life > 300000 hours
Failure rate < 2 fit (0.5 x Ur and 40°C)

Graphs:  

Soldering:

Ur Utest C < 0.33 µF 0.33 µF< C < 10 µF
50 VDC 10 V >5 x 103 M
(mean value: 3×104M)
> 1000 sec (Mx µF)
(mean value: 3000 sec)
63 VDC 50 V >1 x 104 M
(mean value: 5×104M)
> 1250 sec (Mx µF)
(mean value: 3000 sec)
>100 VDC 100 V >1.5 x 104 M
(mean value: 1×105M)
> 3000 sec (Mx µF)
(mean value: 6000 sec)
Measuring time: 1 min.
Dissipation factors at +20°C: tan
at f C < 0.1 µF 0.1 µF< C < 1.0 µF C > 1.0 µF
1 kHz
10 kHz
100 kHz
< 8 x10-3
< 15 x10-3
<
30 x10-3
< 8 x10-3
< 15 x10-3
< 10 x10-3

Maximum pulse rise time: for pulses equal to the rated voltage
Capacitance
µF
Pulse rise time V/µsec
max.operation/test
50VDC 63VDC 100VDC 250VDC 400VDC 630VDC
0.01 …0.022
0.033…0.068
0.1…0.47
0.68…1.0
1.5…3.3
4.7
6.8
 

10



10/100
8/80
8/80
5/50
3/30
 

2.5/25

35/350
20/200
15/150
12/120
7.5/75
5/50
3/30
 

35/350
25/250
20/200
15/150
10/100

 

50/500
50/500
50/500
25/250


 

80/800
80/800
80/800



 

110/1100
90/900




 

Mechanical Tests
Pull test on leads:
10 N in direction of leads according to IEC 60068-2-21
Vibration:
6 hours at 10…2000 Hz and 0.75mm displacement amplitude or 10g in accordance with IEC 60068-2-6
Low air density:
1kPa = 10 mbar in accordance with IEC 60068-2-13
Bump test:
4000 bumps at 390 m/sec2 in accordance with IEC 60068-2-29

Source : http://www.wima.com/EN/mks2.htm